ProtoCessor Manuals and Literature

ProtoCessor Product Data Sheets

Download Format
ProtoCessor OEM Industrial Protocol Modules (pdf) (100K)
ProtoCarrier Daughter Cards (pdf) (133K)
ProtoCessor ProtoConnect Semi-Custom Protocol OEM Board (pdf) (111K)

ProtoCessor Manuals

Download Format
ProtoCessor – Getting Started Guide (pdf) (1020K)
ProtoCessor – Design Guide (pdf) (1679K)
ProtoCarrier 232 DTE User Manual (pdf) (158K)
ProtoCarrier 485 User Manual (pdf) (1200K)
ProtoNode LER and RER StartUp Guide (pdf) (1180K)
ProtoNode BRE – Start-Up Guide (pdf) (126K)
ProtoNode BRE – Instruction Manual (pdf) (613K)
ProtoNode LonWorks– Instruction Manual (pdf) (5870K)
Configuration Manual (pdf) (1544K)
RUInet Utility User Manual (pdf) (50K)
Utilities Manual (pdf) (365K)

ENOTES (Technical Notes)

ENOTE0069-BacNet_Troubleshooting
Download Format
ENOTE0001: Configuration Example (pdf) (67K)
ENOTE0008: Data Array Formats (pdf) (23K)
ENOTE0013: Hierarchy of Timing Parameters (pdf) (29K)
ENOTE0015: Working with Echelon LonWorks Products (pdf) (22K)
ENOTE0025: Interpreting FieldServer Configuration File Error Messages (pdf) (271K)
ENOTE0031: LonWorks - Program ID Calculation (pdf) (22K)
ENOTE0033: N2OPEN Compliancy Using Metasys N2 and BACnet/IP (pdf) (36K)
ENOTE0043: Using Node Status Bits (pdf) (23K)
ENOTE0058: Taking Serial Capture Logs (pdf) (152K)
ENOTE0059: How to Decide Implicit or Explicit Addressing (pdf) (18K)
ENOTE0062: Replacing a Bound FieldServer in LonMaker (pdf) (82K)
ENOTE0063: Ethereal Captures (pdf) (460K)
ENOTE0067: FieldServer Timing Parameters (pdf) (34K)
ENOTE0069: BACnet Troubleshooting (pdf) (86K)
ENOTE0078: Managing the Lon DSN on a FieldServer (pdf) (22K)
ENOTE0080: Recovering a ProtoCessor from a Bad Download (pdf) (65K)
ENOTE0081: Working with Honeywell CARE System (pdf) (488K)
ENOTE0084: ProtoCessor Diagnostics Worksheet (pdf) (257K)
ENOTE0087: Recovering the ProtoNode (pdf) (66K)
ENOTE0090: Recovering the ProtoCessor 9210 (pdf) (340K)

Utility Software

Software Size Description
Ruinet

273kB

Ruinet Utility is the primary utility used with the ProtoCessor. It is used to:

  • Transfer files (configuration, firmware, etc) to and from a ProtoCessor
  • Monitor a working ProtoCessor’s internal data and parameters
  • Change or update a ProtoCessor’s internal data and parameters
  • Delete files on a ProtoCessor
  • Restart a ProtoCessor
Ruiping

137kB Ruiping utility is used to identify the ProtoCessor on the network.
Ruidebug

321kB Ruidebug utility captures information from the ProtoCessor necessary to debug problems
Install.zip

7.1Mb The Install.zip is the latest version of the Install software that is included with the CD shipped originally with the FieldServer. It contains the latest versions of the above utilities plus other useful programs.

Design Documents (OEM Protocol Modules)

Download Format
ProtoCessor Data Pack (package contents can be downloaded individually below) (5456K)
- ProtoCessor Design Guide ProtoCessor socket - PCB footpring.pdf (318K)
- ProtoCessor Socket – PCB Footprint (pdf) ProtoCessor socket - PCB footpring.pdf (39K)
- ProtoCessor Socket – PCB Footprint (dxf) ProtoCessor Sockt - PCB Footpring.dxf (138K)
- Enclosure Mechanical Design (pdf) Proto-Encl.pdf (39K)
- Enclosure Mechanical Design (dxf) Proto-Encl.dxf (492K)
- ProtoCessor Socket – Pin Assignment pin assignment-customer.xls (19K)
- ProtoCessor Recommended Header Pins protocessor_Recommended_Header_Pins.doc (90K)
- ProtoCessor Power Requirements ProtoCessor Power Requirement (17K)
- ProtoCessor Control Protocol (PCP) protocessor_pcp_driver_specification.doc (313K)
- ProtoCessor Simple Protocol (PSP) protocessor_psp_driver_specification.doc (154K)
- FFP-LonWorks (pdf) FFP-Lon.pdf (34K)
- FFP-LonWorks (dxf) FFP-Lon.dxf (591K)
- Modbus RTU Specification (click link) Modbus Site

Downloadable documents:

Download Adobe Reader